Ms. Kong The General Manager
Tel:0086-10-60954830;
Company: Beijing Precision Science of Huateng Technology Co.,Ltd.
Address: Room914, the Building of Xuancheng International ,Mafang Town Pinggu district, Beijing City ,China.
Email:kxyjchina@126.com; www.kxyjchina.com
DELCOM INSTRUMENTS
ADVANTAGES OF EDDY CURRENT TECHNOLOGY |
Nondestructive |
SPECIFICATIONS |
Reads through insulating layers Measures moving material Nearly instantaneous readings Provides real-time process inspection |
Reach into material: Sensor gap: |
20 cm |
3 mm |
Minimum sample size: |
3 cm diameter circle |
Spatial resolution: Reading rate: Reading display rate: |
3 cm diameter circle 30 ms |
REDUCE PRODUCT AND LABOR COSTS |
Automate testing—no more manual probing Test 100% of material without damage Address coating issues as they happen Avoid further processing of out-of-spec material |
240 ms (displays the average of 8 readings) |
APPLICATIONS—Designed for use on glass, wafers, |
film and more, including: |
FEATURES OF THIS CONFIGURATION |
Touch screens, flat screens, ITO, TCOs, etc. Carbon nanotube, graphene, silver nanowire, etc. Semiconductor materials Photovoltaic materials Architectural glass (Low-E), smart glass OLED and LED applications Packaging, decorative films/paper, metalized labels, microwave susceptors, reflective materials Flex circuitry and flexible circuit boards Metalized capacitor foil Low observables |
Measures sheet conductance, sheet resistance, thickness (with known resistivity), and resistivity (with known thickness) |
Simple one-button operation Read via LCD, software, browser, or PC application Swap sensors of other types and ranges Use up to eight sensors at once with one interface module and software |
Software includes automatic sample detection, reading, recording, manual mapping, pass/fail, and exportation to .csv file and Microsoft Excel Remotely read and control sensors with Modbus or web-based application |
Batteries and fuel cells De-icing and heating products Antennas |
Single point, detached, caliper-style sensor Small footprint |
Calibrate meter in less than one minute Automatic compensation for temperature drift |
DATASHEET FOR MODEL: 20J3 Sensor and 873 Interface Module |
Deka
METER RANGES—Delcom meters are available in one of four ranges. |
a distance detector, or calibrating the meter to expect the material at a known elevation. |
From 5 to 100,000 ohms/square From .5 to 10,000 ohms/square From .05 to 1,000 ohms/square From .005 to 100 ohms/square |
ACCURACY—Delcom meters are calibrated to better than 99.9% accuracy against National Institute of Standards and Technology (NIST) standards. User can calibrate a meter with one standard in one minute. |
RESOLUTION—Significant digits available at each order |
REQUIREMENTS |
of magnitude for each of the four meter ranges. |
100–120/200–250 VAC 60/50 Hz |
10°C–60°C |
DIMENSIONS AND WEIGHTS |
LINEARITY—Delcom guarantees no more than 3% deviation from the true sheet resistance value of tested material. The chart below shows a Delcom meter tested against 10 NIST, VLSI, and MSA standards. |
20J3 Sensor: 20J3 Stage: 873 Interface Module: |
33 × 5 × 5 cm, 1 kg |
55 × 47 × 8 cm, 10 kg 22 × 18 × 10 cm, 2 kg 61 × 61 × 16 cm, 13 kg |
20J3 Stage packaged for shipping: |
20J3 and 873 packaged for shipping: |
46 × 41 × 21 cm, 9 kg |
20J3 STAGE—Optional stage for precise sample control. |
REPEATABILITY—Delcom meter readings are effectively 99.9% repeatable if sample placement and environmental factors, such as temperature, are held constant. |
TEMPERATURE COMPENSATION—The baseline readings of eddy current instruments drift with changes in ambient temperature. Delcom benchtop sensors are compensated so they drift no more than .04% of total resolution per degree Celsius per hour. |
SOFTWARE—Optional software includes five different modes optimized for common user applications. |
EFFECTS OF ELEVATION ON READING—The elevation of the conductive layer in the sensor gap affects the meter readings. This effect can be addressed through the use of a stage, automatic compensation with |